裝漏電開關還是先裝空氣開關,對於這個問題肯定很多人都會存在疑問?
kongqikaiguanzhengquedemingchengjiaokongqiduanluqi,yibanshiyonglaiguozaihuoduanlubaohudeng。zhiyaoxianlubuchaoguokongqikaiguanyunxudezuidadianliu,jishifashengloudian,kongqikaiguanyebuhuizidongtiaozhaqieduanxianluzhongdedianyuan。

而漏電開關正確的名稱為剩餘電流保護裝置,是一種具有特殊保護功能(漏電保護)dekongqiduanluqi。chulekongqikaiguandejibengongnengwai,hainengzaifuzaihuiluchuxianloudianshinengxunsufenduankaiguan,yibimianzaifuzaihuiluchuxianloudianshiduirenyuandeshanghaiheduidianqishebeidebuliyingxiang。

一般空氣開關用在線路中作為總開關,而漏電開關作為支路的開關,所以正常的接法應該是先空氣開關再漏電開關。
為(wei)什(shen)麼(me)要(yao)這(zhe)樣(yang)接(jie)呢(ne),從(cong)它(ta)的(de)功(gong)能(neng)上(shang)我(wo)們(men)就(jiu)可(ke)以(yi)知(zhi)道(dao),如(ru)果(guo)把(ba)漏(lou)電(dian)開(kai)關(guan)接(jie)在(zai)空(kong)氣(qi)斷(duan)路(lu)器(qi)的(de)前(qian)麵(mian)。一(yi)旦(dan)漏(lou)電(dian)開(kai)關(guan)出(chu)現(xian)漏(lou)電(dian)就(jiu)會(hui)切(qie)斷(duan)電(dian)源(yuan),而(er)空(kong)氣(qi)開(kai)關(guan)在(zai)這(zhe)個(ge)時(shi)候(hou)不(bu)會(hui)作(zuo)出(chu)反(fan)應(ying),就(jiu)會(hui)導(dao)致(zhi)越(yue)級(ji)跳(tiao)閘(zha)的(de)現(xian)象(xiang)出(chu)現(xian)。也(ye)就(jiu)是(shi)漏(lou)電(dian)開(kai)關(guan)跳(tiao)閘(zha)了(le),空(kong)氣(qi)斷(duan)路(lu)器(qi)卻(que)不(bu)跳(tiao)閘(zha)。

開關越級跳閘會有什麼後果呢?打(da)個(ge)比(bi)方(fang),一(yi)個(ge)工(gong)廠(chang)有(you)十(shi)個(ge)車(che)間(jian),如(ru)果(guo)總(zong)開(kai)關(guan)裝(zhuang)漏(lou)電(dian)開(kai)關(guan),支(zhi)路(lu)也(ye)就(jiu)是(shi)每(mei)個(ge)車(che)間(jian)裝(zhuang)空(kong)氣(qi)開(kai)關(guan)。一(yi)旦(dan)某(mou)個(ge)車(che)間(jian)的(de)線(xian)路(lu)發(fa)生(sheng)漏(lou)電(dian),就(jiu)能(neng)使(shi)總(zong)開(kai)關(guan)跳(tiao)閘(zha),切(qie)斷(duan)電(dian)源(yuan),導(dao)致(zhi)整(zheng)個(ge)廠(chang)區(qu)都(dou)停(ting)電(dian)。這(zhe)也(ye)是(shi)為(wei)什(shen)麼(me)要(yao)把(ba)空(kong)氣(qi)開(kai)關(guan)裝(zhuang)在(zai)漏(lou)電(dian)開(kai)關(guan)前(qian)的(de)原(yuan)因(yin)。
當然像家電用電的,特別是商品房套間,先裝空氣開關還是漏電開關沒有多大的區別,zhuyaoshichuxianduandianyeshiduanzijiade,bingbuhuiyingxiangdaoqitataojiandeshangpinfang。xiangxiaoqudefang,faxianhenduorenzongkaiguanzhuangleloudiankaiguanhaizhuangleyigekongqikaiguan,qishimeibiyao,zongkaiguanzhuangyigekongqikaiguanjiukeyile,fenzhiluzhuangloudiankaiguanjiukeyile。dangranniyaoshiweilegengbaoxianpaloudiankaiguanshilingyekeyizailoudiankaiguanqianzhuangyigekongqikaiguan。
此外,有工友說:工業設備裝漏保的必要性要從多方分析。采用三相五線製,有單獨的重複接地!所(suo)有(you)的(de)用(yong)電(dian)機(ji)具(ju),如(ru),電(dian)機(ji),電(dian)磁(ci)線(xian)圈(quan)有(you)專(zhuan)用(yong)接(jie)地(di)線(xian),櫃(gui)內(nei)一(yi)點(dian)接(jie)地(di)。在(zai)以(yi)上(shang)情(qing)況(kuang)下(xia),可(ke)以(yi)不(bu)用(yong)漏(lou)保(bao),大(da)功(gong)率(lv)漏(lou)保(bao)價(jia)格(ge)是(shi)空(kong)氣(qi)斷(duan)路(lu)器(qi)價(jia)格(ge)2倍以上。
工業設備中的220v用電,一般由控製變壓器提供,這個電壓對大地是懸浮電壓,所以一般不接漏保!當然有很多不合標的工業控櫃,控製用電沒有經過隔離變壓器!這樣最好采用漏保!但故障率挺高的,經常跳閘,反正不規範的工業設備配電,最好采用漏保
(來源:網絡,版權歸原作者)
Copyright© 2013-2026 天津西納智能科技有限公司 版權所有
電話:
傳真:
聯係人:餘子豪
郵箱:
地址:天津市和平區保利國際廣場5號樓3206室
![]()
掃描微信二維碼關注我們